Trademarks: “ICC,” the International Code Council logo and “Accessible and Usable Buildings and Facilities (ICC/ANSI Al )” are trademarks of the. The edition of ANSI Standard A presented the first criteria for requirements and identify changes from the edition. . ICC/ANSI A Major changes/additions from ICC ANSI A – found in the edition of A 1. ICC ANSI. A – Section. ICC ANSI A –

Author: Galabar Moogugami
Country: Laos
Language: English (Spanish)
Genre: Travel
Published (Last): 11 December 2006
Pages: 177
PDF File Size: 15.42 Mb
ePub File Size: 4.84 Mb
ISBN: 711-5-95261-272-9
Downloads: 99828
Price: Free* [*Free Regsitration Required]
Uploader: Tojazilkree

Building Blocks a Forward b Parallel Fig.

Elevator, car controls shall comply with Section The uppercase letter “I” of the font shall be 7, 6 inch 4. Tactile character stroke width shall comply with Section A clear q117 space com- plying with Section shall be provided in front of the machine. Removable in-tub seats shall be 15 inches mm minimum and 16 inches mm maximum in depth. The American National Standards Institute does not develop stan- dards and will in no circumstances give an interpretation of any Ameri- can National Standard.

The bottoms of diagonal curb ramps shall have 48 inches mm minimum clear space outside active traffic lanes of the roadway. Grab nasi shall comply with Section Accessible passenger loading zones shall comply with Section Visual characters shall be 40 inches mm minimum above the floor of the viewing position, measured to the baseline of the character.

ANSI A117.1 (2003): Accessible and Usable Buildings and Facilities

Existing elements shall be per- mitted at 54 inches mm maximum above the floor. The turning space shall be a T-shaped space within a inch 1 mm minimum square, with arms and 1a17 36 inches 91 5 mm minimum in width.

  L4D CVAR PDF

Accessible signs shall comply with Section Changes in level greater than V 2 inch 13 mm in height shall be ramped and shall comply a1117 Sec- tion or The spout shall provide a flow of water 4 inches mm minimum in height.

Grab bars shall have a cross section complying with Section Counter a1177 of adjoining gutters and road surfaces immediately adjacent to the curb ramp shall not be steeper than 1: Automatic doors and automatic gates shall comply with Section The clear floor space shall not be obstructed by bases, enclosures, or seats. When characters are both visual and tactile, the stroke width shall be 10 percent minimum of the height of the uppercase letter “I”.

Thresholds in roil-in-type shower compartment shall be V 2 inch 13 mm max- imum in height in accordance with Section For the purpose of this standard, the terms listed in Section Gripping surfaces shall ifc continuous, without interruption by newel posts, other construction elements, or obstructions.

Access aisles shall be marked so as to discourage parking in them.

A crosswalk or other identified path intended for pedestrian use in crossing a vehicular way. The slope that is perpendicular to the direction of travel see running slope. Operable parts shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist.

  HP 2531 DATASHEET PDF

Full text of “ANSI A (): Accessible and Usable Buildings and Facilities”

Individual Expert IE Nonvoting – Members in this category are individual experts selected to assist the consensus body. Horizontal grab bars shall be provided across the control wall and on the back wall to a point 18 inches mm from the control wall.

Inside handrails on switchback or dogleg stairs or ramps shall be continuous between flights or runs. Iicc landings shall comply with Section ANSI approved the edition on November 26, Type B units shall comply with Section 1 Building Blocks trude 4 inches mm maximum horizontally into the circulation path. Illustrative figures are numbered the 0203 as corre- sponding text to simplify the use of the Standard.

Destination-oriented elevators shall be permitted to have signals visible from the floor area adjacent to the hoistway entrance.

ICC/ANSI A – Accessible and Useable Buildings and Facilities

Extensions shall return to a wall, guard, or floor, ucc shall be continuous to the handrail of an adja- cent ramp run. Enclosures on bathtubs shall not have tracks installed on the rim of the bathtub. These accessible elements are used for designing accessible functional spaces such as classrooms, hotel rooms, lobbies or offices.